Description
The Reichert Tono‑Pen AVIA® builds on the established performance of the classic Tono‑Pen XL to provide fast and versatile intraocular pressure measurement in a lightweight handheld instrument.
Its Quick‑Tap® measurement mode uses an enhanced averaging technique to provide greater measurement confidence in as few as two taps. Operators can select between traditional First Generation Mode, which typically obtains a result in five taps, and Quick‑Tap Second Generation Mode. This faster mode can be particularly useful when examining children or less cooperative patients.
Tono‑Pen AVIA uses Micro Strain Gauge technology to deliver fast and repeatable measurements with minimal operator dependence. The instrument can be operated in virtually any position, making it suitable for seated, wheelchair-bound or bedridden patients.
A one-button interface, dual-sided LCD screens, statistical confidence indicator and ergonomic soft-touch grips support efficient operation by clinicians and trained technicians. Routine calibration is not required, and the replaceable Powercel® battery provides power for thousands of measurements.
The starter kit includes 150 individually wrapped Reichert Ocu‑Film® + Tip Covers to help reduce the risk of cross-contamination and protect the instrument’s transducer.
Key Features
- Quick‑Tap measurement in as few as two taps
- Traditional and Quick‑Tap measurement modes
- No routine calibration required
- Micro Strain Gauge technology
- Statistical confidence indicator
- One-button operation
- Dual-sided LCD screens
- Usable in virtually any position
- Suitable for right- or left-handed operation
- Less sensitive to corneal centration
- Lightweight ergonomic design
- Replaceable long-life Powercel battery
- 150 individually wrapped Ocu‑Film tip covers included
- Designed and assembled in the USA
Measurement Modes
| Mode | Description |
|---|---|
| First Generation Mode | Traditional measurement, typically completed in approximately five taps |
| Quick‑Tap Second Generation Mode | Enhanced averaging technique that can provide a measurement in as few as two taps |
Additional Information
| Specification | Value |
|---|---|
| Product type | Handheld applanation tonometer |
| Catalog number | 230650 |
| Measurement range | 5–55 mmHg |
| Transducer | Micro Strain Gauge |
| Measurement modes | First Generation and Quick‑Tap |
| Display | Dual-sided LCD |
| Measurement assessment | Statistical confidence indicator |
| Calibration | No routine calibration required |
| Power source | Tono‑Pen AVIA Powercel battery pack |
| Length | 6.25 in / 16 cm |
| Width | 0.75 in / 2 cm |
| Thickness | 1.75 in / 4.4 cm |
| Weight | 2.4 oz / 71 g |
| Operating orientation | Gravity independent |
| Operator handling | Right- or left-handed |
Starter Kit Contents
- Tono‑Pen AVIA tonometer
- Protective carrying case
- 150 individually wrapped Ocu‑Film® + Tip Covers
- Tono‑Pen AVIA Powercel battery pack
Important Use Notice
The cornea must be prepared according to the manufacturer’s clinical instructions, including the use of topical anesthetic. Use a new, genuine Reichert Ocu‑Film + Tip Cover for every patient. Non-Reichert covers may cause erratic or inaccurate readings and may contaminate the transducer.