Description
The MediWorks T170 R Type is a slit-lamp-mounted applanation tonometer designed to measure intraocular pressure according to the Goldmann principle.
Its pivoting R-type configuration positions the measurement prism in front of the slit-lamp microscope. This allows the practitioner to measure intraocular pressure while the patient remains seated at the slit lamp and to integrate tonometry with other routine microscopic examinations.
The calibrated mechanical system and precision optical prism are designed to provide consistent clinical measurements across a range of 0 to 80 mmHg. Its adjustable construction supports accurate positioning and reliable operation in routine ophthalmology and optometry environments.
The T170 R Type is compatible with applicable tower-style slit lamps. MediWorks specifically lists compatibility with the S360, S360s and S390L when the appropriate R-type adapter is used. Compatibility with other slit lamps must be confirmed before ordering.
The manufacturer indicates that three prisms are supplied in the standard package. The slit lamp and mounting adapter should be confirmed separately in the quotation.
- Based on the Goldmann applanation principle
- Measures intraocular pressure—IOP
- Measurement range from 0 to 80 mmHg
- R-type pivoting mounting configuration
- Designed for use with compatible slit lamps
- Precision mechanical measurement system
- 7 mm optical prism
- Prism movement of ±1.5 mm
- Supports repeatable clinical measurements
- Compact and lightweight construction
- Three prisms published as standard package contents
- Suitable for glaucoma assessment and monitoring
Additional Information
- Product type: Slit-lamp-mounted applanation tonometer
- Mounting configuration: R Type
- Measurement principle: Goldmann applanation
- Measurement range: 0–80 mmHg
- Equivalent pressure range: 0–10.64 kPa
- Movement range of the rings: 1.53 × 2 = 3.06 mm
- Prism diameter: 7 mm
- Prism movement range: ±1.5 mm
- Dimensions: 190 × 80 × 80 mm
- Net weight: 480 g
- Published compatibility: S360, S360s and S390L slit lamps with applicable R-type mounting
- Power requirement: None; mechanical instrument
Recommended Applications
- Measurement of intraocular pressure
- Glaucoma screening support
- Monitoring patients with glaucoma
- Evaluation of ocular hypertension
- Routine ophthalmology examinations
- Optometry and specialized eye-care practices
- Integration with slit-lamp examinations
Standard Package
According to the manufacturer’s published information, the standard package includes:
- One T170 R Type applanation tonometer
- Three measurement prisms
- Applicable standard accessories
Important Note
The slit lamp is not included. The correct R-type adapter may be required and should be confirmed for the specific slit-lamp model before ordering.
Applanation tonometry involves contact with the cornea and must be performed by a qualified professional using the appropriate clinical protocol, topical anesthetic, fluorescein and properly disinfected prisms. Follow the manufacturer’s instructions for cleaning, disinfection and use.